Safety & Compliance
Last updated: 15 October 2026 · Breethr HQ, Inc. | 131 Continental Drive, Suite 305, Newark, Delaware 19713
Use P1 safely
Use Breethr P1 only for the purposes and conditions stated in its user manual. Read the operating and installation instructions before setting up or using the product. Keep air paths clear and do not use damaged cables, insecure mounts, unsupported window setups or altered safety components.
Important precautions
P1 requires a grounded 110 V, single-phase, 60 Hz supply on a dedicated 20 A circuit. Do not use extension cords. The outdoor unit weighs 50 kg (110 lb) and requires two people for lifting. Wall-mount the outdoor unit only on concrete or brick using the specified hardware, or use the specified anchored floor-mount arrangement. Secure the indoor unit to supports rated for its weight.
Do not modify or service sealed refrigerant circuits, high-voltage parts, fixed building wiring or other safety-critical equipment unless qualified and authorized to do so. In the event of abnormal noise, smoke, overheating, damage or unsafe operation, stop use safely and contact support@breethr.com.
Air quality and sensor information
Climate and air-quality readings shown by P1 or its app are informational and may depend on sensor conditions and placement. P1 is not a medical device, a substitute for required ventilation, or a replacement for smoke and carbon monoxide alarms. Performance varies with the room, installation and local conditions.
Compliance and maintenance
Keep air paths clear and the outdoor unit free of leaves, snow and debris. Check mounts, pipe couplings, gaskets and cables periodically, and stop use if any are loose, damaged or worn. P1 uses four filter stages: pre-filter, fine filter, H14 HEPA and carbon. Filters are consumable parts; follow the supplied care instructions for cleaning and replacement. The refrigerant circuit is factory sealed. For service, contact support@breethr.com with your order number.
Product ratings: grounded 110 V, single-phase, 60 Hz supply on a dedicated 20 A circuit; nominal cooling capacity 1 TR (12,000 BTU/h); nominal coverage up to 250 sq ft; heating element input 1,200 W; fan input 120 W per fan. Heating and cooling are separate modes and never run together. Cooling capacity and coverage are nominal figures, and heating-element and fan inputs are component figures, not total system power consumption. Actual performance depends on operating and room conditions.
Breethr is completing the applicable product safety and regulatory certifications for the US market. Certification details will appear on the product rating label and in the supplied safety instructions.